中国食品网

§172.864 食品添加剂合成脂肪醇(Synthetic fatty alcohols)

2011-05-03 中国食品网 中食网 415 0

  § 172.864 Synthetic fatty alcohols.

  Synthetic fatty alcohols may be safely used in food and in the synthesis of food components in accordance with the following prescribed conditions:

  (a) The food additive consists of any one of the following fatty alcohols:

  (1) Hexyl, octyl, decyl, lauryl, myristyl, cetyl, and stearyl; manufactured by fractional distillation of alcohols obtained by a sequence of oxidation and hydrolysis of organo-aluminums generated by the controlled reaction of low molecular weight trialkylaluminum with purified ethylene (minimum 99 percent by volume C2H4), and utilizing the hydrocarbon solvent as defined in paragraph (b) of this section, such that:

  (i) Hexyl, octyl, decyl, lauryl, and myristyl alcohols contain not less than 99 percent of total alcohols and not less than 96 percent of straight chain alcohols. Any nonalcoholic impurities are primarily paraffins.

  (ii) Cetyl and stearyl alcohols contain not less than 98 percent of total alcohols and not less than 94 percent of straight chain alcohols. Any nonalcoholic impurities are primarily paraffins.

  (iii) The synthetic fatty alcohols contain no more than 0.1 weight percent of total diols as determined by a method available upon request from the Commissioner of Food and Drugs.

  (2) Hexyl, octyl, and decyl; manufactured by fractional distillation of alcohols obtained by a sequence of oxidation, hydrolysis, and catalytic hydrogenation (catalyst consists of copper, chromium, and nickel) of organo-aluminums generated by the controlled reaction of low molecular weight trialkylaluminum with purified ethylene (minimum 99 percent by volume C2H4), and utilizing an external coolant such that these alcohols meet the specifications prescribed in paragraph (a)(1) (i) and (iii) of this section.

  (3) n-Octyl; manufactured by the hydrodimerization of 1,3-butadiene, followed by catalytic hydrogenation of the resulting dienol, and distillation to produce n -octyl alcohol with a minimum purity of 99 percent. The analytical method for n -octyl alcohol entitled “Test Method [Normal-octanol]” dated October 2003, and printed by Kuraray Co., Ltd., is incorporated by reference. The Director of the Office of the Federal Register approves this incorporation by reference in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. You may obtain a copy from the Office of Food Additive Safety, 5100 Paint Branch Pkwy., College Park, MD 20740, or you may examine a copy at the Center for Food Safety and Applied Nutrition's Library, Food and Drug Administration, 5100 Paint Branch Pkwy., College Park, MD 20740, or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202–741–6030, or go tohttp://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.

  (b) The hydrocarbon solvent used in the process described in paragraph (a)(1) of this section is a mixture of liquid hydrocarbons essentially paraffinic in nature, derived from petroleum and refined to meet the specifications described in paragraph (b)(1) of this section when subjected to the procedures described in paragraph (b) (2) and (3) of this section.

  (1) The hydrocarbon solvent meets the following specifications:

  (i) Boiling-point range: 175 °C–275 °C.

  (ii) Ultraviolet absorbance limits as follows:

Wavelength (millicrons) Maximum absorbance per centimeter optical path length
280–289 0.15
290–299 0.12
300–359 0.05
360–400 0.02


  (2) Use ASTM method D86–82, “Standard Method for Distillation of Petroleum Products,” which is incorporated by reference, to determine boiling point range. Copies of the material incorporated by reference may be obtained from the American Society for Testing Materials, 100 Barr Harbor Dr., West Conshohocken, Philadelphia, PA 19428-2959, or may be examined at the National Archives and Records Administration (NARA)。 For information on the availability of this material at NARA, call 202–741–6030, or go to:http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.

  (3) The analytical method for determining ultraviolet absorbance limits is as follows:

  General Instructions

  All glassware should be scrupulously cleaned to remove all organic matter such as oil, grease, detergent residues, etc. Examine all glassware, including stoppers and stopcocks, under ultraviolet light to detect any residual fluorescent contamination. As a precautionary measure, it is recommended practice to rinse all glassware with purified isooctane immediately before use. No grease is to be used on stopcocks or joints. Great care to avoid contamination of hydrocarbon solvent samples in handling and to assure absence of any extraneous material arising from inadequate packaging is essential. Because some of the polynuclear hydrocarbons sought in this test are very susceptible to photo-oxidation, the entire procedure is to be carried out under subdued light.

  Apparatus

  Chromatographic tube. 450 millimeters in length (packing section), inside diameter 19 millimeters ±1 millimeter, equipped with a wad of clean Pyrex brand filtering wool (Corning Glass Works Catalog No. 3950 or equivalent)。 The tube shall contain a 250-milliliter reservoir and a 2-millimeter tetrafluoroethylene polymer stopcock at the opposite end. Overall length of the tube is 670 millimeters.

  Stainless steel rod. 2 feet in length, 2 to 4 millimeters in diameter.

  Vacuum oven. Similar to Labline No. 3610 but modified as follows: A copper tube one-fourth inch in diameter and 13 inches in length is bent to a right angle at the 4-inch point and plugged at the opposite end; eight copper tubes one-eighth inch in diameter and 5 inches in length are silver soldered in drilled holes (one-eighth inch in diameter) to the one-fourth-inch tube, one on each side at the 5-, 7.5-, 10- and 12.5-inch points; the one-eighth-inch copper tubes are bent to conform with the inner periphery of the oven.

  Beakers. 250-milliliter and 500-milliliter capacity.

  Graduated cylinders. 25-milliliter, 50-milliliter, and 150-milliliter capacity.

  Tuberculin syringe. 1-milliliter capacity, with 3-inch, 22-gauge needle.

  Volumetric flask. 5-milliliter capacity.

  Spectrophotometric cells. Fused quartz ground glass stoppered cells, optical path length in the range of 1.000 centimeter ±0.005 centimeter. With distilled water in the cells, determine any absorbance difference.

  Spectrophotometer. Spectral range 250 millimicrons—400 millimicrons with spectral slit width of 2 millimicrons or less: under instrument operating conditions for these absorbance measurements, the spectrophotometer shall also meet the following performance requirements:

  Absorbance repeatability, ±0.01 at 0.4 absorbance.

  Absorbance accuracy,1 ±0.05 at 0.4 absorbance.

1As determined by using potassium chromate for reference standard and described in National Bureau of Standards Circular 484, Spectrophotometry, U.S. Department of Commerce, (1949)。 The accuracy is to be determined by comparison with the standard values at 290, 345, and 400 millimicrons. Circular 484 is incorporated by reference. Copies are available from the Center for Food Safety and Applied Nutrition (HFS–200), Food and Drug Administration, 5100 Paint Branch Pkwy., College Park, MD 20740, or available for inspection at the National Archives and Records Administration (NARA)。 For information on the availability of this material at NARA, call 202–741–6030, or go to:http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.

  Wavelength repeatability, ±0.2 millimicron.

  Wavelength accuracy, ±1.0 millimicron.

  Nitrogen cylinder. Water-pumped or equivalent purity nitrogen in cylinder equipped with regulator and valve to control flow at 5 p.s.i.g.

  Reagents and Materials

  Organic solvents. All solvents used throughout the procedure shall meet the specifications and tests described in this specification. The isooctane, benzene, hexane, and 1,2-dichloroethane designated in the list following this paragraph shall pass the following test:

  To the specified quantity of solvent in a 250-milliliter beaker, add 1 milliliter of purified n- hexadecane and evaporate in the vacuum oven under a stream of nitrogen. Discontinue evaporation when not over 1 milliliter of residue remains. (To the residue from benzene add a 5-milliliter portion of purified isooctane, reevaporate, and repeat once to insure complete removal of benzene.)

  Dissolve the 1 milliliter of hexadecane residue in isooctane and make to 5 milliliters volume. Determine the absorbance in the 1-centimeter path length cells compared to isooctane as reference. The absorbance of the solution of the solvent residue shall not exceed 0.02 per centimeter path length between 280 and 300 mμ and shall not exceed 0.01 per centimeter path length between 300 and 400 mμ。

  Isooctane ( 2,2,4-trimethylpentane )。 Use 10 milliliters for the test described in the preceding paragraph. If necessary, isooctane may be purified by passage through a column of activated silica gel (Grade 12, Davison Chemical Co., Baltimore, Md., or equivalent)。

  Benzene, spectro grade ( Burdick and Jackson Laboratories, Inc., Muskegon, Mich., or equivalent )。 Use 80 milliliters for the test. If necessary, benzene may be purified by distillation or otherwise.

  Hexane, spectro grade ( Burdick and Jackson Laboratories, Inc., Muskegon, Mich., or equivalent )。 Use 650 milliliters for the test. If necessary, hexane may be purified by distillation or otherwise.

  1,2-Dichloroethane, spectro grade ( Matheson, Coleman, and Bell, East Rutherford, N.J., or equivalent )。 Use 20 milliliters for test. If necessary, 1,2-dichloroethane may be purified by distillation.

  Eluting mixtures:

  1. 10 percent 1,2-dichloroethane in hexane. Pipet 100 milliliters of 1,2-dichloroethane into a 1-liter glass-stoppered volumetric flask and adjust to volume with hexane, with mixing.

  2. 40 percent benzene in hexane. Pipet 400 milliliters of benzene into a 1-liter glass-stoppered volumetric flask and adjust to volume with hexane, with mixing.

  n-Hexadecane, 99 percent olefin-free. Dilute 1.0 milliliter of n- hexadecane to 5 milliliters with isooctane and determine the absorbance in a 1-centimeter cell compared to isooctane as reference between 280 mμ-400mμ。 The absorbance per centimeter path length shall not exceed 0.00 in this range. If necessary, n- hexadecane may be purified by percolation through activated silica gel or by distillation.

  Silica gel, 28–200 mesh ( Grade 12, Davison Chemical Co., Baltimore, Md., or equivalent )。 Activate as follows: Weigh about 900 grams into a 1-gallon bottle, add 100 milliliters of de-ionized water, seal the bottle and shake and roll at intervals for 1 hour. Allow to equilibrate overnight in the sealed bottle. Activate the gel at 150 °C for 16 hours, in a 2-inch × 7-inch × 12-inch porcelain pan loosely covered with aluminum foil, cool in a dessicator, transfer to a bottle and seal.

  Procedure

  Determination of ultraviolet absorbance. Before proceeding with the analysis of a sample determine the absorbance in a 1-centimeter path cell for the reagent blank by carrying out the procedure without a sample. Record the absorbance in the wavelength range of 280 to 400 millimicrons. Typical reagent blank absorbance in this range should not exceed 0.04 in the 280 to 299 millimicron range, 0.02 in the 300 to 359 millimicron range, and 0.01 in the 360 to 400 millimicron range. If the characteristic benzene peaks in the 250 to 260 millimicron region are present, remove the benzene by the procedure described above under “Reagents and Materials,” “Organic Solvents,” and record absorbance again.

  Transfer 50 grams of silica gel to the chromatographic tube for sample analysis. Raise and drop the column on a semisoft, clean surface for about 1 minute to settle the gel. Pour 100 milliliters of hexane into the column with the stopcock open and allow to drain to about one-half inch above the gel. Turn off the stopcock and allow the column to cool for 30 minutes. After cooling, vibrate the column to eliminate air and stir the top 1 to 2 inches with a small diameter stainless steel rod. Take care not to get the gel above the liquid and onto the sides of the column.

  Weigh out 40 grams ±0.1 gram of the hydrocarbon solvent sample into a 250-milliliter beaker, add 50 milliliters of hexane, and pour the solution into the column. Rinse the beaker with 50 milliliters of hexane and add this to the column. Allow the hexane sample solution to elute into a 500-milliliter beaker until the solution is about one-half inch above the gel. Rinse the column three times with 50-milliliter portions of hexane. Allow each hexane rinse to separately elute to about one-half inch above the gel. Replace the eluate beaker (discard the hexane eluate) with a 250-milliliter beaker. Add two separate 25-milliliter portions of 10 percent 1,2-dichloroethane and allow each to separately elute as before. Finally, add 150 milliliters of 10 percent 1,2-dichloroethane for a total of 200 milliliters. When the final 10 percent 1,2-dichloroethane fraction is about one-half inch above the top of the gel bed, replace the receiving beaker (discard the 1,2-dichloroethane eluate) with a 250-milliliter beaker containing 1 milliliter of hexadecane. Adjust the elution rate to 2 to 3 milliliters per minute, add two 25-milliliter portions of 40 percent benzene and allow each to separately elute as before to within about one-half inch of the gel bed. Finally, add 150 milliliters of 40 percent benzene for a total of 200 milliliters. Evaporate the benzene in the oven with vacuum and sufficient nitrogen flow to just ripple the top of the benzene solution. When the benzene is removed (as determined by a constant volume of hexadecane) add 5 milliliters of isooctane and evaporate. Repeat once to insure complete removal of benzene. Remove the beaker and cover with aluminum foil (previously rinsed with hexane) until cool.

  Quantitatively transfer the hexadecane residue to a 5-milliliter volumetric flask and dilute to volume with isooctane. Determine the absorbance of the solution in 1-centimeter path length cells between 280 and 400 millimicrons using isooctane as a reference. Correct the absorbance values for any absorbance derived from reagents as determined by carrying out the procedure without a sample. If the corrected absorbance does not exceed the limits prescribed in paragraph (b)(1)(ii) of this section, the sample meets the ultraviolet absorbance specifications for hydrocarbon solvent.

  (c) Synthetic fatty alcohols may be used as follows:

  (1) As substitutes for the corresponding naturally derived fatty alcohols permitted in food by existing regulations in this part or part 173 of this chapter provided that the use is in compliance with any prescribed limitations.

  (2) As substitutes for the corresponding naturally derived fatty alcohols used as intermediates in the synthesis of food additives and other substances permitted in food.

  [42 FR 14491, Mar. 15, 1977, as amended at 47 FR 11837, Mar. 19, 1982; 49 FR 10105, Mar. 19, 1984; 54 FR 24897, June 12, 1989; 70 FR 72908, Dec. 8, 2005]

  更多关于美国 FDA 已批准的直接用于人类食品的添加剂种类法规,请点击美国FDA 21 CFR 第172部分已批准的直接用于人类食品的添加剂种类汇总

更多国外法规翻译,请联系食品翻译中心
编辑:foodfagui

举报0 收藏0 打赏0 评论0
推荐图文
推荐资讯
点击排行
    网站首页| 关于我们| 新手帮助| 信息发布规则| 版权隐私| 服务条款| 联系我们| 网站地图| 排名推广| 广告服务| 积分换礼| RSS订阅| 违规举报
    Baidu
    map